Sign In | Join Free | My benadorassociates.com
China Shanghai Hengyi Mechanical&Electrical Engineering Co., Ltd. logo
Shanghai Hengyi Mechanical&Electrical Engineering Co., Ltd.
Shanghai Hengyi Mechanical&Electrical Engineering Co., Ltd.
Active Member

4 Years

Home > ev charger tester >

4P 63A 80A 30mA RCCB Residual Current Device Circuit Breaker RCD

Shanghai Hengyi Mechanical&Electrical Engineering Co., Ltd.
Contact Now

4P 63A 80A 30mA RCCB Residual Current Device Circuit Breaker RCD

Contact Now

4P 63A 80A 30mA RCCB Residual Current Device Circuit Breaker RCD

Short Description:

Type B RCCBs, in addition to normal AC, can detect high frequency AC and pure DC earth leakage currents. Reducing the risk of fire and/or electrocution through automatic disconnection of the electrical supply relies on the selection of the correct type of RCCB.Provides protection against earth fault/leakage current and function of isolation.

High short-circuit current withstand capacity. Applicable to terminal and pin/fork type busbar connection. Equipped with finger protected connection terminals. Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity. Independent of power supply and line voltage, and free from external interference, voltage fluctuation.


  • Rated Current: 16A, 25A,32A ,40A, 63A, 80A 100A
  • Poles: 2Pole (1P+N) , 4Pole (3P+N)
  • Rated voltage: 2Pole: 230V/240V , 4Pole: 400V/415V
  • Rated frequency 50/60Hz
  • Rated residual operation current: 30mA ,100mA ,300mA
  • Short-circuit current Inc=: I c 10000A
  • Standard: IEC 61008-1 , IEC 62423
  • Send email to usSend email to us

    Product Detail

    Product Tags

    Type B RCCBs, in addition to normal AC, can detect high frequency AC and pure DC earth leakage currents. Reducing the risk of fire and/or electrocution through automatic disconnection of the electrical supply relies on the selection of the correct type of RCCB.

    Function
    Control electric circuits.
    Protect people against indirect contacts and additionalprotection against direct contacts.
    Protect installations against fire hazard due to insulation faults.

    Technical Data

    1. Provides protection against earth fault/leakage current and function of isolation.

    2. High short-circuit current withstand capacity.

    3. Applicable to terminal and pin/fork type busbar connection.

    4. Equipped with finger protected connection terminals.

    5. Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity.

    6. Independent of power supply and line voltage, and free from external interference, voltage fluctuation.

    Residual Current Circuit Breaker is applicable to electric circuits with rated voltage 230/400V AC, frequency 50/60Hz and rated current up to 80Amp.

    1. RCCB with rated sensitivity up to 30mA could be used as supplementary protecting device in case other protecting device fails its protection against electric shock.
    2. RCCB designed for household installation and other similar application, is for non-professional operation, and no maintenance is required.
    3. RCCB provides no protection against electric shock resulted from direct contacts of both protected lines,or leakage current between these two lines.
    4. Particular devices such as surge protective devices,surge arrester etc are recommended to install at upstream line to RCCB as precaution against potential surge voltage and current occurring at its power input side.
    5. Satisfying conditions and applications as mentioned above, RCCB withON-OFFindicating device is considered suitable for isolation function.

    Item Type B RCD / Type B RCCB
    Product Model EKL6-100B
    Type B Type
    Rated Current 16A , 25A , 32A , 40A , 63A , 80A ,100A
    Poles 2Pole ( 1P+N ),4Pole ( 3P+N )
    Rated voltage Ue 2Pole240V ~,4Pole415V~
    Insulation Voltage 500V
    Rated frequency 50/60Hz
    Rated residual operation current(I n) 30mA , 100mA , 300mA
    Short-circuit current Inc= I c 10000A
    SCPD fuse 10000
    Break time under I n ≤0.1s
    Dielectric test voltage at ind.Freq. for 1min 2.5kV
    Electrical life 2,000 Cycles
    Mechanical life 4,000 Cycles
    Protection Degree IP20
    Ambient temperature -5℃ upto +40℃
    Storage temperature -25℃ upto +70℃
    Terminal connection type Cable/Pin type busbar
    U-type busbar
    Terminal siz










    Quality 4P 63A 80A 30mA RCCB Residual Current Device Circuit Breaker RCD for sale

    4P 63A 80A 30mA RCCB Residual Current Device Circuit Breaker RCD Images

    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shanghai Hengyi Mechanical&Electrical Engineering Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)